aboutsummaryrefslogtreecommitdiff
path: root/Documentation/i2c/chips/lm80
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/i2c/chips/lm80')
-rw-r--r--Documentation/i2c/chips/lm8056
1 files changed, 0 insertions, 56 deletions
diff --git a/Documentation/i2c/chips/lm80 b/Documentation/i2c/chips/lm80
deleted file mode 100644
index cb5b407ba3e..00000000000
--- a/Documentation/i2c/chips/lm80
+++ /dev/null
@@ -1,56 +0,0 @@
-Kernel driver lm80
-==================
-
-Supported chips:
- * National Semiconductor LM80
- Prefix: 'lm80'
- Addresses scanned: I2C 0x28 - 0x2f
- Datasheet: Publicly available at the National Semiconductor website
- http://www.national.com/
-
-Authors:
- Frodo Looijaard <frodol@dds.nl>,
- Philip Edelbrock <phil@netroedge.com>
-
-Description
------------
-
-This driver implements support for the National Semiconductor LM80.
-It is described as a 'Serial Interface ACPI-Compatible Microprocessor
-System Hardware Monitor'.
-
-The LM80 implements one temperature sensor, two fan rotation speed sensors,
-seven voltage sensors, alarms, and some miscellaneous stuff.
-
-Temperatures are measured in degrees Celsius. There are two sets of limits
-which operate independently. When the HOT Temperature Limit is crossed,
-this will cause an alarm that will be reasserted until the temperature
-drops below the HOT Hysteresis. The Overtemperature Shutdown (OS) limits
-should work in the same way (but this must be checked; the datasheet
-is unclear about this). Measurements are guaranteed between -55 and
-+125 degrees. The current temperature measurement has a resolution of
-0.0625 degrees; the limits have a resolution of 1 degree.
-
-Fan rotation speeds are reported in RPM (rotations per minute). An alarm is
-triggered if the rotation speed has dropped below a programmable limit. Fan
-readings can be divided by a programmable divider (1, 2, 4 or 8) to give
-the readings more range or accuracy. Not all RPM values can accurately be
-represented, so some rounding is done. With a divider of 2, the lowest
-representable value is around 2600 RPM.
-
-Voltage sensors (also known as IN sensors) report their values in volts.
-An alarm is triggered if the voltage has crossed a programmable minimum
-or maximum limit. Note that minimum in this case always means 'closest to
-zero'; this is important for negative voltage measurements. All voltage
-inputs can measure voltages between 0 and 2.55 volts, with a resolution
-of 0.01 volt.
-
-If an alarm triggers, it will remain triggered until the hardware register
-is read at least once. This means that the cause for the alarm may
-already have disappeared! Note that in the current implementation, all
-hardware registers are read whenever any data is read (unless it is less
-than 2.0 seconds since the last update). This means that you can easily
-miss once-only alarms.
-
-The LM80 only updates its values each 1.5 seconds; reading it more often
-will do no harm, but will return 'old' values.