diff options
Diffstat (limited to 'fs/cifs/inode.c')
-rw-r--r-- | fs/cifs/inode.c | 109 |
1 files changed, 69 insertions, 40 deletions
diff --git a/fs/cifs/inode.c b/fs/cifs/inode.c index 5ab9896fdcb..4690a360c85 100644 --- a/fs/cifs/inode.c +++ b/fs/cifs/inode.c @@ -199,6 +199,49 @@ static void fill_fake_finddataunix(FILE_UNIX_BASIC_INFO *pfnd_dat, pfnd_dat->Gid = cpu_to_le64(pinode->i_gid); } +/** + * cifs_new inode - create new inode, initialize, and hash it + * @sb - pointer to superblock + * @inum - if valid pointer and serverino is enabled, replace i_ino with val + * + * Create a new inode, initialize it for CIFS and hash it. Returns the new + * inode or NULL if one couldn't be allocated. + * + * If the share isn't mounted with "serverino" or inum is a NULL pointer then + * we'll just use the inode number assigned by new_inode(). Note that this can + * mean i_ino collisions since the i_ino assigned by new_inode is not + * guaranteed to be unique. + */ +struct inode * +cifs_new_inode(struct super_block *sb, __u64 *inum) +{ + struct inode *inode; + + inode = new_inode(sb); + if (inode == NULL) + return NULL; + + /* + * BB: Is i_ino == 0 legal? Here, we assume that it is. If it isn't we + * stop passing inum as ptr. Are there sanity checks we can use to + * ensure that the server is really filling in that field? Also, + * if serverino is disabled, perhaps we should be using iunique()? + */ + if (inum && (CIFS_SB(sb)->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM)) + inode->i_ino = (unsigned long) *inum; + + /* + * must set this here instead of cifs_alloc_inode since VFS will + * clobber i_flags + */ + if (sb->s_flags & MS_NOATIME) + inode->i_flags |= S_NOATIME | S_NOCMTIME; + + insert_inode_hash(inode); + + return inode; +} + int cifs_get_inode_info_unix(struct inode **pinode, const unsigned char *full_path, struct super_block *sb, int xid) { @@ -233,22 +276,11 @@ int cifs_get_inode_info_unix(struct inode **pinode, /* get new inode */ if (*pinode == NULL) { - *pinode = new_inode(sb); + *pinode = cifs_new_inode(sb, &find_data.UniqueId); if (*pinode == NULL) { rc = -ENOMEM; goto cgiiu_exit; } - /* Is an i_ino of zero legal? */ - /* note ino incremented to unique num in new_inode */ - /* Are there sanity checks we can use to ensure that - the server is really filling in that field? */ - if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM) - (*pinode)->i_ino = (unsigned long)find_data.UniqueId; - - if (sb->s_flags & MS_NOATIME) - (*pinode)->i_flags |= S_NOATIME | S_NOCMTIME; - - insert_inode_hash(*pinode); } inode = *pinode; @@ -465,11 +497,9 @@ int cifs_get_inode_info(struct inode **pinode, /* get new inode */ if (*pinode == NULL) { - *pinode = new_inode(sb); - if (*pinode == NULL) { - rc = -ENOMEM; - goto cgii_exit; - } + __u64 inode_num; + __u64 *pinum = &inode_num; + /* Is an i_ino of zero legal? Can we use that to check if the server supports returning inode numbers? Are there other sanity checks we can use to ensure that @@ -486,22 +516,26 @@ int cifs_get_inode_info(struct inode **pinode, if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM) { int rc1 = 0; - __u64 inode_num; rc1 = CIFSGetSrvInodeNumber(xid, pTcon, - full_path, &inode_num, + full_path, pinum, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (rc1) { cFYI(1, ("GetSrvInodeNum rc %d", rc1)); + pinum = NULL; /* BB EOPNOSUPP disable SERVER_INUM? */ - } else /* do we need cast or hash to ino? */ - (*pinode)->i_ino = inode_num; - } /* else ino incremented to unique num in new_inode*/ - if (sb->s_flags & MS_NOATIME) - (*pinode)->i_flags |= S_NOATIME | S_NOCMTIME; - insert_inode_hash(*pinode); + } + } else { + pinum = NULL; + } + + *pinode = cifs_new_inode(sb, pinum); + if (*pinode == NULL) { + rc = -ENOMEM; + goto cgii_exit; + } } inode = *pinode; cifsInfo = CIFS_I(inode); @@ -621,7 +655,7 @@ static const struct inode_operations cifs_ipc_inode_ops = { .lookup = cifs_lookup, }; -static char *build_path_to_root(struct cifs_sb_info *cifs_sb) +char *cifs_build_path_to_root(struct cifs_sb_info *cifs_sb) { int pplen = cifs_sb->prepathlen; int dfsplen; @@ -678,7 +712,7 @@ struct inode *cifs_iget(struct super_block *sb, unsigned long ino) return inode; cifs_sb = CIFS_SB(inode->i_sb); - full_path = build_path_to_root(cifs_sb); + full_path = cifs_build_path_to_root(cifs_sb); if (full_path == NULL) return ERR_PTR(-ENOMEM); @@ -1017,7 +1051,7 @@ out_reval: return rc; } -static void posix_fill_in_inode(struct inode *tmp_inode, +void posix_fill_in_inode(struct inode *tmp_inode, FILE_UNIX_BASIC_INFO *pData, int isNewInode) { struct cifsInodeInfo *cifsInfo = CIFS_I(tmp_inode); @@ -1114,24 +1148,14 @@ int cifs_mkdir(struct inode *inode, struct dentry *direntry, int mode) else direntry->d_op = &cifs_dentry_ops; - newinode = new_inode(inode->i_sb); + newinode = cifs_new_inode(inode->i_sb, + &pInfo->UniqueId); if (newinode == NULL) { kfree(pInfo); goto mkdir_get_info; } - /* Is an i_ino of zero legal? */ - /* Are there sanity checks we can use to ensure that - the server is really filling in that field? */ - if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM) { - newinode->i_ino = - (unsigned long)pInfo->UniqueId; - } /* note ino incremented to unique num in new_inode */ - if (inode->i_sb->s_flags & MS_NOATIME) - newinode->i_flags |= S_NOATIME | S_NOCMTIME; newinode->i_nlink = 2; - - insert_inode_hash(newinode); d_instantiate(direntry, newinode); /* we already checked in POSIXCreate whether @@ -1285,6 +1309,11 @@ int cifs_rmdir(struct inode *inode, struct dentry *direntry) cifsInode = CIFS_I(direntry->d_inode); cifsInode->time = 0; /* force revalidate to go get info when needed */ + + cifsInode = CIFS_I(inode); + cifsInode->time = 0; /* force revalidate to get parent dir info + since cached search results now invalid */ + direntry->d_inode->i_ctime = inode->i_ctime = inode->i_mtime = current_fs_time(inode->i_sb); |