From cc0680a580b5be81a1ca321b58f8e9b80b5c1052 Mon Sep 17 00:00:00 2001 From: Tejun Heo Date: Mon, 6 Aug 2007 18:36:23 +0900 Subject: libata-link: linkify reset Make reset methods and related functions deal with ata_link instead of ata_port. * ata_do_reset() * ata_eh_reset() * all prereset/reset/postreset methods and related functions This patch introduces no behavior change. Signed-off-by: Tejun Heo Signed-off-by: Jeff Garzik --- drivers/ata/pata_sil680.c | 7 ++++--- 1 file changed, 4 insertions(+), 3 deletions(-) (limited to 'drivers/ata/pata_sil680.c') diff --git a/drivers/ata/pata_sil680.c b/drivers/ata/pata_sil680.c index 40395804a66..45515a22d85 100644 --- a/drivers/ata/pata_sil680.c +++ b/drivers/ata/pata_sil680.c @@ -95,15 +95,16 @@ static int sil680_cable_detect(struct ata_port *ap) { /** * sil680_bus_reset - reset the SIL680 bus - * @ap: ATA port to reset + * @link: ATA link to reset * @deadline: deadline jiffies for the operation * * Perform the SIL680 housekeeping when doing an ATA bus reset */ -static int sil680_bus_reset(struct ata_port *ap,unsigned int *classes, +static int sil680_bus_reset(struct ata_link *link, unsigned int *classes, unsigned long deadline) { + struct ata_port *ap = link->ap; struct pci_dev *pdev = to_pci_dev(ap->host->dev); unsigned long addr = sil680_selreg(ap, 0); u8 reset; @@ -112,7 +113,7 @@ static int sil680_bus_reset(struct ata_port *ap,unsigned int *classes, pci_write_config_byte(pdev, addr, reset | 0x03); udelay(25); pci_write_config_byte(pdev, addr, reset); - return ata_std_softreset(ap, classes, deadline); + return ata_std_softreset(link, classes, deadline); } static void sil680_error_handler(struct ata_port *ap) -- cgit v1.2.3