aboutsummaryrefslogtreecommitdiff
path: root/Documentation/hwmon
diff options
context:
space:
mode:
authorHans de Goede <hdegoede@redhat.com>2009-06-15 18:39:52 +0200
committerJean Delvare <khali@linux-fr.org>2009-06-15 18:39:52 +0200
commit09475d32e652fe60901fe8c9cd50f3f6db0c4933 (patch)
tree895d7f0d2195e6e6902b6fc8f56cdc4228f0913f /Documentation/hwmon
parentb6858bca8d7bf52e2564cba5a5ed87e1019d3fd9 (diff)
hwmon: (f71882fg) Add support for the F71858F
Add support for the hwmon part of the Fintek F71858FG superio IC to the f71882fg driver. Many thanks to Jelle de Jong for lending me a motherboard with this superio on it. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/f71882fg12
1 files changed, 8 insertions, 4 deletions
diff --git a/Documentation/hwmon/f71882fg b/Documentation/hwmon/f71882fg
index a8321267b5b..bee4c30bc1e 100644
--- a/Documentation/hwmon/f71882fg
+++ b/Documentation/hwmon/f71882fg
@@ -2,14 +2,18 @@ Kernel driver f71882fg
======================
Supported chips:
- * Fintek F71882FG and F71883FG
- Prefix: 'f71882fg'
+ * Fintek F71858FG
+ Prefix: 'f71858fg'
Addresses scanned: none, address read from Super I/O config space
Datasheet: Available from the Fintek website
* Fintek F71862FG and F71863FG
Prefix: 'f71862fg'
Addresses scanned: none, address read from Super I/O config space
Datasheet: Available from the Fintek website
+ * Fintek F71882FG and F71883FG
+ Prefix: 'f71882fg'
+ Addresses scanned: none, address read from Super I/O config space
+ Datasheet: Available from the Fintek website
* Fintek F8000
Prefix: 'f8000'
Addresses scanned: none, address read from Super I/O config space
@@ -66,13 +70,13 @@ printed when loading the driver.
Three different fan control modes are supported; the mode number is written
to the pwm#_enable file. Note that not all modes are supported on all
-chips, and some modes may only be available in RPM / PWM mode on the F8000.
+chips, and some modes may only be available in RPM / PWM mode.
Writing an unsupported mode will result in an invalid parameter error.
* 1: Manual mode
You ask for a specific PWM duty cycle / DC voltage or a specific % of
fan#_full_speed by writing to the pwm# file. This mode is only
- available on the F8000 if the fan channel is in RPM mode.
+ available on the F71858FG / F8000 if the fan channel is in RPM mode.
* 2: Normal auto mode
You can define a number of temperature/fan speed trip points, which % the