power: pcf50633: get rid of charging restart software auto-triggering
After reaching Battery Full condition MBC state machine switches back
into charging mode when the battery voltage falls below 96% of a
battery float voltage. The voltage drop in Li-Ion batteries is
marginal (1-2%) till about 80% of its capacity - which means, after a
BATFULL, charging won't be restarted until 75-80%.
That is a desired behaviour recommended by battery manufacturers,
don't mess with it.