diff options
author | Nathan Lynch <ntl@pobox.com> | 2008-12-10 14:46:06 +0000 |
---|---|---|
committer | Paul Mackerras <paulus@samba.org> | 2008-12-21 14:21:14 +1100 |
commit | 13ba3c0092b4db272d1f643206c1b55f4fe415a6 (patch) | |
tree | 0d583fc57b0820bba6f678974dbc4c09e1d636aa /arch | |
parent | b2ea25b958968c152c6fac0594f2c9aa8b59eb8d (diff) |
powerpc: Convert sysfs cache code to of_find_next_cache_node()
Using the common code means that more complete cache information will
provided in sysfs on platforms that don't use the l2-cache property
convention.
Signed-off-by: Nathan Lynch <ntl@pobox.com>
Signed-off-by: Paul Mackerras <paulus@samba.org>
Diffstat (limited to 'arch')
-rw-r--r-- | arch/powerpc/kernel/sysfs.c | 7 |
1 files changed, 1 insertions, 6 deletions
diff --git a/arch/powerpc/kernel/sysfs.c b/arch/powerpc/kernel/sysfs.c index 20885a38237..0c64f10087b 100644 --- a/arch/powerpc/kernel/sysfs.c +++ b/arch/powerpc/kernel/sysfs.c @@ -566,7 +566,6 @@ static bool cache_is_unified(struct device_node *np) static struct cache_desc * __cpuinit create_cache_index_info(struct device_node *np, struct kobject *parent, int index, int level) { - const phandle *next_cache_phandle; struct device_node *next_cache; struct cache_desc *new, **end; @@ -591,11 +590,7 @@ static struct cache_desc * __cpuinit create_cache_index_info(struct device_node while (*end) end = &(*end)->next; - next_cache_phandle = of_get_property(np, "l2-cache", NULL); - if (!next_cache_phandle) - goto out; - - next_cache = of_find_node_by_phandle(*next_cache_phandle); + next_cache = of_find_next_cache_node(np); if (!next_cache) goto out; |