aboutsummaryrefslogtreecommitdiff
path: root/drivers/net/e1000e/ich8lan.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/net/e1000e/ich8lan.c')
-rw-r--r--drivers/net/e1000e/ich8lan.c107
1 files changed, 106 insertions, 1 deletions
diff --git a/drivers/net/e1000e/ich8lan.c b/drivers/net/e1000e/ich8lan.c
index 0e0755f0db3..d56c7473144 100644
--- a/drivers/net/e1000e/ich8lan.c
+++ b/drivers/net/e1000e/ich8lan.c
@@ -461,6 +461,95 @@ static s32 e1000_init_mac_params_ich8lan(struct e1000_adapter *adapter)
return 0;
}
+/**
+ * e1000_check_for_copper_link_ich8lan - Check for link (Copper)
+ * @hw: pointer to the HW structure
+ *
+ * Checks to see of the link status of the hardware has changed. If a
+ * change in link status has been detected, then we read the PHY registers
+ * to get the current speed/duplex if link exists.
+ **/
+static s32 e1000_check_for_copper_link_ich8lan(struct e1000_hw *hw)
+{
+ struct e1000_mac_info *mac = &hw->mac;
+ s32 ret_val;
+ bool link;
+
+ /*
+ * We only want to go out to the PHY registers to see if Auto-Neg
+ * has completed and/or if our link status has changed. The
+ * get_link_status flag is set upon receiving a Link Status
+ * Change or Rx Sequence Error interrupt.
+ */
+ if (!mac->get_link_status) {
+ ret_val = 0;
+ goto out;
+ }
+
+ if (hw->mac.type == e1000_pchlan) {
+ ret_val = e1000e_write_kmrn_reg(hw,
+ E1000_KMRNCTRLSTA_K1_CONFIG,
+ E1000_KMRNCTRLSTA_K1_ENABLE);
+ if (ret_val)
+ goto out;
+ }
+
+ /*
+ * First we want to see if the MII Status Register reports
+ * link. If so, then we want to get the current speed/duplex
+ * of the PHY.
+ */
+ ret_val = e1000e_phy_has_link_generic(hw, 1, 0, &link);
+ if (ret_val)
+ goto out;
+
+ if (!link)
+ goto out; /* No link detected */
+
+ mac->get_link_status = false;
+
+ if (hw->phy.type == e1000_phy_82578) {
+ ret_val = e1000_link_stall_workaround_hv(hw);
+ if (ret_val)
+ goto out;
+ }
+
+ /*
+ * Check if there was DownShift, must be checked
+ * immediately after link-up
+ */
+ e1000e_check_downshift(hw);
+
+ /*
+ * If we are forcing speed/duplex, then we simply return since
+ * we have already determined whether we have link or not.
+ */
+ if (!mac->autoneg) {
+ ret_val = -E1000_ERR_CONFIG;
+ goto out;
+ }
+
+ /*
+ * Auto-Neg is enabled. Auto Speed Detection takes care
+ * of MAC speed/duplex configuration. So we only need to
+ * configure Collision Distance in the MAC.
+ */
+ e1000e_config_collision_dist(hw);
+
+ /*
+ * Configure Flow Control now that Auto-Neg has completed.
+ * First, we need to restore the desired flow control
+ * settings because we may have had to re-autoneg with a
+ * different link partner.
+ */
+ ret_val = e1000e_config_fc_after_link_up(hw);
+ if (ret_val)
+ hw_dbg(hw, "Error configuring flow control\n");
+
+out:
+ return ret_val;
+}
+
static s32 e1000_get_variants_ich8lan(struct e1000_adapter *adapter)
{
struct e1000_hw *hw = &adapter->hw;
@@ -2224,6 +2313,14 @@ static s32 e1000_reset_hw_ich8lan(struct e1000_hw *hw)
}
}
+ /*
+ * For PCH, this write will make sure that any noise
+ * will be detected as a CRC error and be dropped rather than show up
+ * as a bad packet to the DMA engine.
+ */
+ if (hw->mac.type == e1000_pchlan)
+ ew32(CRC_OFFSET, 0x65656565);
+
ew32(IMC, 0xffffffff);
icr = er32(ICR);
@@ -2538,6 +2635,14 @@ static s32 e1000_get_link_up_info_ich8lan(struct e1000_hw *hw, u16 *speed,
if (ret_val)
return ret_val;
+ if ((hw->mac.type == e1000_pchlan) && (*speed == SPEED_1000)) {
+ ret_val = e1000e_write_kmrn_reg(hw,
+ E1000_KMRNCTRLSTA_K1_CONFIG,
+ E1000_KMRNCTRLSTA_K1_DISABLE);
+ if (ret_val)
+ return ret_val;
+ }
+
if ((hw->mac.type == e1000_ich8lan) &&
(hw->phy.type == e1000_phy_igp_3) &&
(*speed == SPEED_1000)) {
@@ -2984,7 +3089,7 @@ static void e1000_clear_hw_cntrs_ich8lan(struct e1000_hw *hw)
static struct e1000_mac_operations ich8_mac_ops = {
.id_led_init = e1000e_id_led_init,
.check_mng_mode = e1000_check_mng_mode_ich8lan,
- .check_for_link = e1000e_check_for_copper_link,
+ .check_for_link = e1000_check_for_copper_link_ich8lan,
/* cleanup_led dependent on mac type */
.clear_hw_cntrs = e1000_clear_hw_cntrs_ich8lan,
.get_bus_info = e1000_get_bus_info_ich8lan,