Currently these values are initialized by the callers. This was exposed
by a later patch that adds PLOGI request support. The patch failed to
initialize the new remote port's roles and it caused problems. This patch
has the rport_create routine initialize the identifiers and then the
callers can override them with real values.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
It's possible to "restart" discovery before it was started if
an RSCN is received early enough. We were jumping to 0
due to the disc_callback function pointer not getting set.
Don't restart discovery if disc_callback is NULL.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The discovery code had a special-case for the point-to-point mode,
which used a bunch of code that wasn't really needed.
Now that rport_create adds the rport to the discovery list,
completely skip discovery for the point-to-point case.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
In fc_disc_gpn_ft_parse(), after fc_disc_done() is called, the
disc state is changed by setting buf_len = 0. This is wrong
since the discovery may have restarted. Instead, return
after calling fc_disc_done.
Also, return an error on memory allocation failure.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Currently fc_disc_timeout() restarts discovery only if it is not pending.
When the timer is scheduled, the discovery is left pending, so the
timeout never restarts it.
Fix by not checking for pending in the timeout handler.
If discovery is stopped and restarted in the meantime, the timeout will
be canceled.
Also, when a new discovery is started, the retry count wasn't cleared.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
On some switches, an empty zone causes GPN_FT to be rejected
with reason 9 (unable) explanation 7 (FC-4 types not registered),
which causes discovery to be retried endlessly. Treat this as
just an empty response and consider discovery complete.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Abhijeet Joglekar wrote: "In gpn_ft_resp, if the payload is short,
or unexpected response or out of sequence frame, then we just
return and do nothing. We should either enter fc_disc_done()
with DISC_EV_FAIL which will then restart any queued discovery
requests or call lport module which will reset local port,
or we should call fc_disc_error() so that the gpn_ft is retried.
The situation as is causes discovery to remain pending and never
get restarted, in these rare cases. We saw this due to a coding
bug in fc_disc before. The only ways it could happen would be
bugs, packet corruption or an FC fabric problem.
Change it to fail discovery. The local port will restart
discovery, although it probably should just give up until
the next link flap.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Code cleanup for fc_disc_gpn_ft_resp().
Some of the fc_disc.c code was poorly formatted. For example, some lines
in fc_disc.c were unnecessarily truncated and the buf variable could
be eliminated.
Also moved the increment of seq_count into fc_disc_gpn_ft_parse(), to
avoid doing it separately before each call.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
When an RSCN is received during fabric discovery, it restarts.
After the restart, disc->seq_count was incremented, so when
the first frame was received, it was considered "out of sequence".
That left the state disc->active, preventing further discoveries.
Change to advance the sequence count before parsing, so that it
won't be changed after a potential restart.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
When receiving an RSCN, do not log off all rports. This is
extremely disruptive. If, after the GPN_FT response, some
rports haven't been listed, delete them.
Add field disc_id to structs fc_rport_priv and fc_disc.
disc_id is an arbitrary serial number used to identify the
rports found by the latest discovery. This eliminates the need
to go through the rport list when restarting discovery.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Move the libfc remote port lookup function into fc_rport.c.
This seems like the best place for it.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Since the rport list maintenance is now done in the rport module,
the callback (and ops) are usually not necessary.
Allow rdata->ops to be left NULL if nothing needs
to be done in an event callback.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
For future discovery patches, change rport_create to return a previously
created rport_priv that has the FC_ID as long as it isn't in deleted state.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The list of remote ports (struct fc_rport_priv) has been
maintained by the discovery module. In preparation for having
lport->tt.rport_create() do a lookup first, maintain the
rports list in the rport module. It will still be protected
by the disc_mutex.
The DNS rport is an exception for until after further patches.
For now, do not add it to the list.
The point-to-point rport will be in the discovery list.
So at shutdown, it doesn't need to be separately logged out.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The lport rport callback can only be called for the dNS rport,
since its the only rport who's ops point to that function.
Remove unnecessary checking and debug messages.
Put the locking outside the switch statement as a simplification.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Don't print large negative decimal numbers for frame pointers in
the debug messages from fc_rport_error(). Just print 0 if its a
frame pointer, and print the error numbers as positive.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Delete unused disc->delay element.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
There was no need to have the discovery status stored in struct fc_disc.
Change fc_disc_done() to take the discovery status as an argument
and just pass it on to the discovery callback.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
When a remote port becomes ready and a LOGO is received before
the READY event is in rport_work waiting on the mutex, the
event is changed to LOGO and the work queued, so both the
calls to rport_work see the LOGO event, and both try to do
the list_del(), causing a crash.
Don't change the event if it is already set.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Don't create a "dummy" remote port to go with fc_rport_priv.
Make the rport truly optional by allocating fc_rport_priv separately
and not requiring a dummy rport to be there if we haven't yet done
fc_remote_port_add().
The fc_rport_libfc_priv remains as a structure attached to the
rport for I/O purposes.
Be sure to hold references on rdata when the lock is dropped in
fc_rport_work().
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Remote ports will become READY more than once after
ADISC is implemented in a later patch.
The event callback that has been called "CREATED" will mean "READY".
Rename it now in preparation for those changes.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
This is a cleanup without semantic changes to use a switch
statement instead of a series of if-statements in fc_rport_work(),
and to move some declarations up to the top.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Allow a struct fc_rport_priv to have no fc_rport associated with it.
This sets up to remove the need for "rogue" rports.
Add a few fields to fc_rport_priv that are needed before the fc_rport
is created. These are the ids, maxframe_size, classes, and rport pointer.
Remove the macro PRIV_TO_RPORT(). Just use rdata->rport where appropriate.
To take the place of the get_device()/put_device ops that were used to
hold both the rport and rdata, add a reference count to rdata structures
using kref. When kref_get decrements the refcount to zero, a new template
function releasing the rdata should be called. This will take care of
freeing the rdata and releasing the hold on the rport (for now). After
subsequent patches make the rport truly optional, this release function
will simply free the rdata.
Remove the simple inline function fc_rport_set_name(), which becomes
semanticly ambiguous otherwise. The caller will set the port_name and
node_name in the rdata->Ids, which will later be copied to the rport
when it its created.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
tt.elsct_send is used by both FCP and by the rport state machine.
After further patches, these two modules will use different
structures for the remote port.
So, change elsct_send to use the FC_ID instead of the fc_rport_priv
as its argument. It currently only uses the FC_ID anyway.
For CT requests the destination FC_ID is still implicitly 0xfffffc.
After further patches the did arg on CT requests will be used to
specify the FC_ID being inquired about for GPN_ID or other queries.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The rport and discovery modules deal with remote ports
before fc_remote_port_add() can be done, because the
full set of rport identifiers is not known at early stages.
In preparation for splitting the fc_rport/fc_rport_priv allocation,
make fc_rport_priv the primary interface for the remote port and
discovery engines.
The FCP / SCSI layers still deal with fc_rport and
fc_rport_libfc_priv, however.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
These macros introduce extra undesirable semicolons that keep
them from being used in expressions, and they don't protect
against being passed an expression.
Add parens and remove the semicolons.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The interface for lport->tt.rport_create() takes a fc_disc_port arg,
which is unnatural for most calls. The only reason for this was
to avoid passing in the local port as an argument, but otherwise
added to complexity.
Simplify by just using lport and fc_rport_identifiers.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
While the I/O and LLD interfaces use fc_rport_libfc_priv, the
disc and rport interfaces will use fc_rport_priv, which will
be separately allocated.
Change the disc and rport usage of fc_rport_libfc_priv to fc_rport_priv.
Use #define temporarily to make both names equivalent until a
subsequent patch splits them.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
This just cuts down on the number of locks we're dealing with, and
eliminates the need to take another lock in the netdev notifier.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Fixes reference counting on fcoe_instance and net_device, and adds
NETDEV_UNREGISTER notifier handling so that you can unload network drivers.
FCoE no longer increments the module use count for the network driver.
On an NETDEV_UNREGISTER event, destroying the FCoE instance is deferred to a
workqueue context to avoid RTNL deadlocks.
Based in part by an earlier patch from John Fastabend
John's patch description:
Currently, the netdev module ref count is not decremented with module_put()
when the module is unloaded while fcoe instances are present. To fix this
removed reference count on netdev module completely and added functionality to
netdev event handling for NETDEV_UNREGISTER events.
This allows fcoe to remove devices cleanly when the netdev module is unloaded
so we no longer need to hold a reference count for the netdev module.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
We only want the FCoE create and destroy routines to deal with top level
N_Ports, the VN_Ports are tracked on the vport list (see scsi_transport_fc).
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Rather than rely on the hostlist_lock to be held while creating exchange
managers, serialize fcoe instance creation and destruction with a mutex.
This will allow the hostlist addition to be moved out of fcoe_if_create(),
which will simplify NPIV support.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
fcoe_netdev_config() is called during initialization of a libfc instance.
Much of what was there only needs to be done once for each net_device.
The same goes for the corresponding cleanup.
The FIP controller initialization is moved to interface creation time.
Otherwise it will keep getting re-initialized for every VN_Port once NPIV is
enabled.
fcoe_if_destroy() has some reordering to deal with the changes. Receives are
not stopped until after fcoe_interface_put() is called, but transmits must be
stopped before. So there is some care to stop libfc transmits and the
transmit backlog timer, then call fcoe_interface_put which will stop receives
and cleanup the FIP controller, then the receive queues can be cleaned and the
port freed.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Up to this point the fcoe_instance structure was simply kzalloc/kfreed. This
patch introduces create and destroy functions as well as kref based reference
counting. The create function will grow as the initialization code is moved
there.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The priv pointer is no longer needed, and once NPIV is enabled
fcoe_interface:fc_lport becomes a one-to-many relationship.
Remove the single pointer.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
fcoe_interface
The offload EM pointer is only used when setting up a new libfc instance, but
as it's designed to be shared among NPIV VN_Ports it should be tracked in
fcoe_interface.
With the host-list changed to track fcoe_interfaces as well, this is needed
before we can remove the priv pointer from that structure (which is only there
to help in the transition, and stops making sense once NPIV is enabled).
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
There is only one FIP state per net_device, so the FIP controller needs to be
moved from the per-SCSI-host fcoe_port to the per-net_device fcoe_interface
structure.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The packet handlers need to be tracked in fcoe_interface so there is only one
set per net_device. When NPIV is enabled there will be multiple SCSI hosts
and multiple fcoe_port structures on a single net_device.
The packet handlers match by ethertype and netdev. If the same handler gets
registered on a single netdev multiple times, the receive function will be
called multiple times for each frame.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The network interface needs to be shared between all NPIV VN_Ports, therefor
it should be tracked in the fcoe_interface and not for each SCSI host in
fcoe_port.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
net_device
In preparation for NPIV support, I'm splitting the fcoe instance structure
into two to remove the assumptions about it being 1:1 with the net_device.
There will now be two structures, one which is 1:1 with the underlying
net_device and one which is allocated per virtual SCSI/FC host.
fcoe_softc is renamed to fcoe_port for the per Scsi_Host FCoE private data.
Later patches with start moving shared stuff from fcoe_port to fcoe_interface
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
By passing in the parent device instead of assuming the netdev is what
should be used, fcoe_if_create becomes usable for NPIV vports as well.
You still need a netdev, because that's how FCoE works. Also removed some
duplicate checks from fcoe_if_create that are already in fcoe_create.
fcoe_if_destroy needs to take an lport as it's only argument, not a netdev.
That removes the 1:1 netdev:lport assumption from the destroy path.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The hostlist and the hostlist_lock were initialized both in
the delcaration and in fcoe_init(). Remove the unneeded code.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
fcoe_if_init() can fail, but it's return value wasn't checked
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Use cancel_work_sync() in place of flush_work(), so that
fcoe_ctlr_destroy() can be called from a workqueue.
Also, purge the receive queue after the recv_work has been cancled because
if recv_work isn't run it's not guaranteed to be empty now.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
This adds fcoe_ddp_min as a module parameter for fcoe module to:
/sys/module/fcoe/parameters/ddp_min
It is observed that for some hardware, particularly Intel 82599, there is too
much overhead in setting up context for direct data placement (DDP) read when
the requested read I/O size is small. This is added as a module parameter for
performance tuning and is set as 0 by default and user can change this based
on their own hardware.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
em_lock
1. Updates fcoe_rcv() to queue incoming frames to the fcoe per
cpu thread on which this frame's exch was originated and simply
use current cpu for request exch not originated by initiator.
It is redundant to add this code under CONFIG_SMP, so removes
CONFIG_SMP uses around this code.
2. Updates fc_exch_em_alloc, fc_exch_delete, fc_exch_find to use
per cpu exch pools, here fc_exch_delete is rename of older
fc_exch_mgr_delete_ep since ep/exch are now deleted in pools
of EM and so brief new name is sufficient and better name.
Updates these functions to map exch id to their index into exch
pool using fc_cpu_mask, fc_cpu_order and EM min_xid.
This mapping is as per detailed explanation about this in
last patch and basically this is just as lower fc_cpu_mask
bits of exch id as cpu number and upper bit sum of EM min_xid
and exch index in pool.
Uses pool next_index to keep track of exch allocation from
pool along with pool_max_index as upper bound of exches array
in pool.
3. Adds exch pool ptr to fc_exch to free exch to its pool in
fc_exch_delete.
4. Updates fc_exch_mgr_reset to reset all exch pools of an EM,
this required adding fc_exch_pool_reset func to reset exches
in pool and then have fc_exch_mgr_reset call fc_exch_pool_reset
for each pool within each EM for a lport.
5. Removes no longer needed exches array, em_lock, next_xid, and
total_exches from struct fc_exch_mgr, these are not needed after
use of per cpu exch pool, also removes not used max_read,
last_read from struct fc_exch_mgr.
6. Updates locking notes for exch pool lock with fc_exch lock and
uses pool lock in exch allocation, lookup and reset.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Adds per cpu exch pool for these reasons:-
1. Currently an EM instance is shared across all cpus to manage
all exches for all cpus. This required em_lock across all
cpus for an exch alloc, free, lookup and reset each frame
and that made em_lock expensive, so instead having per cpu
exch pool with their own per cpu pool lock will likely reduce
locking contention in fast path for an exch alloc, free and
lookup.
2. Per cpu exch pool will likely improve cache hit ratio since
all frames of an exch will be processed on the same cpu on
which exch originated.
This patch is only prep work to help in keeping complexity of next
patch low, so this patch only sets up per cpu exch pool and related
helper funcs to be used by next patch. The next patch fully makes
use of per cpu exch pool in all code paths ie. tx, rx and reset.
Divides per EM exch id range equally across all cpus to setup per
cpu exch pool. This division is such that lower bits of exch id
carries cpu number info on which exch originated, later a simple
bitwise AND operation on exch id of incoming frame with fc_cpu_mask
retrieves cpu number info to direct all frames to same cpu on which
exch originated. This required a global fc_cpu_mask and fc_cpu_order
initialized to max possible cpus number nr_cpu_ids rounded up to 2's
power, this will be used in mapping exch id and exch ptr array
index in pool during exch allocation, find or reset code paths.
Adds a check in fc_exch_mgr_alloc() to ensure specified min_xid
lower bits are zero since these bits are used to carry cpu info.
Adds and initializes struct fc_exch_pool with all required fields
to manage exches in pool.
Allocates per cpu struct fc_exch_pool with memory for exches array
for range of exches per pool. The exches array memory is followed
by struct fc_exch_pool.
Adds fc_exch_ptr_get/set() helper functions to get/set exch ptr in
pool exches array at specified array index.
Increases default FCOE_MAX_XID to 0x0FFF from 0x07EF, so that more
exches are available per cpu after above described exch id range
division across all cpus to each pool.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
error
If using code like this:
if (foo)
FCOE_DBG("foo\n);
else
FCOE_DBG("bar\n");
one gets compile errors because FCOE_DBG expands with its own semicolon,
making one too many for the if-statement.
Remove the offending semicolon in fcoe.h and also a similar case
in libfcoe.c.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The statement reads, "Exchange timed out, notifying the upper layer",
however, this statement is printed whenever the timer is armed. This
is confusing to someone debugging the code because every time an
exchange is initialized, there is an incorrect statement stating that
the timer has already timed out. This patch changes the statement to
read, "Exchange timer armed" which is more accurate.
This patch also adds a debug statement in the timeout handler to
properly indicate that the exchange has timed out.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
There's currently no space between the interface name and the
user specified format/string. This patch adds a space and a colon
to the output to separate the interface name and the user
specified string.
So, instead of "ethXfoo" it will read "ethX: foo".
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|