diff options
author | Thomas White <taw@physics.org> | 2023-09-01 17:18:51 +0200 |
---|---|---|
committer | Thomas White <taw@physics.org> | 2023-09-01 17:18:51 +0200 |
commit | d170ca538a234ea0de20722c5453d2cd7d4e0ef8 (patch) | |
tree | 7d1ee3b16d98e0661d68647b3b1ed37487ecba99 /doc | |
parent | 3f6dbaccbc7c8f4950fcbcd5498794286a981c48 (diff) |
Manual page for adjust_detector (using Pandoc)
Diffstat (limited to 'doc')
-rw-r--r-- | doc/man/adjust_detector.1.md | 100 |
1 files changed, 100 insertions, 0 deletions
diff --git a/doc/man/adjust_detector.1.md b/doc/man/adjust_detector.1.md new file mode 100644 index 00000000..741d7af8 --- /dev/null +++ b/doc/man/adjust_detector.1.md @@ -0,0 +1,100 @@ +% adjust_detector(1) + +NAME +==== + +adjust_detector - move detector panels + + +SYNOPSIS +======== + +adjust_detector -g _input.geom_ -o _output.geom_ -p _group_ [_movement_] + + +DESCRIPTION +=========== + +**adjust_detector** moves a panel (or group of panels) in a CrystFEL detector +geometry file, and writes an updated geometry file. + +To rotate a panel, use one of **--rotx**, **--roty** or **--rotz**. The +rotation will be in degrees, clockwise when looking along the specified axis. +The center of rotation will be the centroid of the corners of the panel, or the +centroid of all the panel centers in the specified group. + +To translate a panel or group, use one of **--shiftx**, **--shifty** or +**--shiftz**. The translation will be along the positive direction of the +specified axis. The units are pixels, unless you additionall specify +**--mm**. + +You can use multiple movements together, but the results are unspecified if you +combine a rotation with any other movement. + + +OPTIONS +======= + +**-g** _input.geom_ +: Specify the input geometry filename. + +**-o** _output.geom_ +: Specify the output geometry filename. +: Note that the geometry file will be re-written, meaning that any formatting +: and comments will be lost. + +**-p** _group_ +: Specify the panel, or panel group, to move. + +**--mm** +: Interpret panel shifts as millimetres, not pixels. + +**--shiftx=***n*, **--shifty=***n*, **--shiftz=***n* +: Shift the chosen panel (or group) by _n_ along the given direction, in units +: of pixels (unless **--mm** is used). When moving a group of panels, the +: pixel size of the *first* panel will be used. + +**--rotx=***n*, **--roty=***n*, **--rotz=***n* +: Shift the chosen panel (or group) by _n_ degrees clockwise about the given +: axis. The center of rotation will be the centroid of the corners of the +: panel, or the centroid of all the panel centers in the specified group. + + +AUTHOR +====== + +This page was written by Thomas White. + + +REPORTING BUGS +============== + +Report bugs to <taw@physics.org>, or visit <http://www.desy.de/~twhite/crystfel>. + + +COPYRIGHT AND DISCLAIMER +======================== + +Copyright © 2023 Deutsches Elektronen-Synchrotron DESY, a research centre of +the Helmholtz Association. + +adjust_detector, and this manual, are part of CrystFEL. + +CrystFEL is free software: you can redistribute it and/or modify it under the +terms of the GNU General Public License as published by the Free Software +Foundation, either version 3 of the License, or (at your option) any later +version. + +CrystFEL is distributed in the hope that it will be useful, but WITHOUT ANY +WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A +PARTICULAR PURPOSE. See the GNU General Public License for more details. + +You should have received a copy of the GNU General Public License along with +CrystFEL. If not, see <http://www.gnu.org/licenses/>. + + +SEE ALSO +======== + +**crystfel**(7), **indexamajig**(1), **align_detector**(1), +**crystfel_geometry**(5) |