aboutsummaryrefslogtreecommitdiff
path: root/include/asm-xtensa/fcntl.h
diff options
context:
space:
mode:
authorJean Delvare <khali@linux-fr.org>2007-06-17 16:09:12 +0200
committerMark M. Hoffman <mhoffman@lightlink.com>2007-07-19 14:22:15 -0400
commit158ce07564b68d4215b9560213a089d6f7c5a4ea (patch)
tree97483b4ab6d8d051164def0429082a8efdb503e2 /include/asm-xtensa/fcntl.h
parente432dc811bfb6b3d3ad618d99bd8d58132fec316 (diff)
hwmon/w83627ehf: Preserve speed reading when changing fan min
The w83627ehf driver changes the fan clock divider automatically when a new min fan speed is set. It is supposed to preserve the fan speed reading while doing so, bug doesn't really. Fix it. Signed-off-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com>
Diffstat (limited to 'include/asm-xtensa/fcntl.h')
0 files changed, 0 insertions, 0 deletions